Examples of Modbus/RTU-CAN converter_GCAN
The user can use the included serial debugging assistant to send Modbus instruction debugging. Please note: choose "hexadecimal display" and "hexadecimal send" when using the serial debugging assistant.
-
Configuration Instructions for Modbus/RTU-CAN converter_GCAN
Open the shell of the converter, find the DIP switch shown below, turn switch 2 to "ON", then connected to the power supply, you can enter the configuration mode. Please note: GCAN-204 uses RS485 interface to configure, do not connect the "M
-
Use Of Modbus/RTU-CAN converter_GCAN
The working principle of GCAN-204, as shown in figure 3.1.
-
Introduce The Product Of Modbus/RTU-CAN converter_GCAN
GCAN-204 converter has one CAN-Bus interface, one serial interface. The GCAN-204 integrates the Modbus RTU protocol. With the GCAN-204 , user can use the serial bus connect to other equipment (with Modbus RTU protocol) access the CAN-Bus com
-
Application Examples of CANBlue_GCAN
GCAN-203 uses 9-30V DC power supply. Connect CAN_H to CAN-Bus CAN_H, CAN_L to CAN-Bus CAN_L. A High-speed CAN bus must be terminated on both ends with 120 Ohms. Otherwise disturbances may arise. As shown in figure 4.1, the left side of the
-
CANBlue config software Introduction_GCAN
Disconnect the GCAN-203 power supply. We can connect to GCAN-203 and computer with USB. When GCAN-203 is configuring, no external power is required. GCAN-203 factory setting: CAN-Bus baud is 250K, working mode is normal mode, name is SN num
-