Modbus IO coupler
- Brand:
- GCAN
- Model:
- GCAN-IO-8100
- Application:
- Decentralized data collection Remote IO control
-
terminal module, and these terminal modules can be expanded in a modular way. A complete
node consists of a bus coupler, 1-32 arbitrary number of terminal modules and a terminalmodule
GCAN-IO-8100 ModbusBus Coupler uses standard Modbus protocol, a standard slave station.
The GCAN-IO-8100 Bus Coupler has two kinds of style, GCAN-IO-8100-TCP supports Modbus
TCP communication, GCAN-IO-8100-RTU supports Modbus RTU communication. Besides,
the firmware can be upgraded by configuring the interface.
GCAN-IO-8100 Bus Coupler supports automatic configuration, and you do not need to set
parameters on the PC. When GCAN-IO-8100 bus coupler uses Modbus RTU communication,
communication parameters can be configured by RS485 interface; When uses Modbus TCP
communication, communication parameters can be configured by Ethernet interface
· Support Modbus TCP, Modbus RTU communication (corresponding to two kinds of style)
· RS485 interface adopts standard two-wires system
· Serial interface baud rate supports 600bps~115200bps, configured by serial interface
· The maximum number of bus terminals module is 64
· Configuration mode is automatic configuration, expandedfreely
· Ethernet interface supports static or dynamic IP acquisition
· Ethernet interface supports heartbeat and timeout disconnection
· Ethernetwork interface is fixed, target IP and target interface can be set
· Automatic restoration of connection resources after the Ethernet interface is disconnected,
and reliable establishment of TCP connections
· Ethernet interface is compatible with the SOCKET working mode (TCP Server, TCP Client,
UDP, etc.). The upper computer communication software complies with the standard SOCKET rules.
· Supply power: 24V DC (-15%/+20%)
· Input current, 70mA+ (total GC-bus current), maximum 4500mA
· Starting current: about 2.5 times continuous current
· Power contacts: maximum 24V DC/maximum 10A
· Electrical isolation: 1000 Vrms (power contact/bus coupled powervoltage)
· Working temperature: -40.00℃~ 85.00℃
· Standard DIN rail,designed for industrial design
· Dimensions:100mm(L) * 69mm(W) * 48mm(H)
PLC Parameters Modbus protocol Modbus TCP,Modbus RTU Bus terminal module quantity Up to 32 modules The biggest byte number of profibus 32bytes input and 32bytes output Digital I/O signal 256 input/output Analog I/O signal 60 input /output Configuration mode automatic configuration Bus interface RJ45 Power 24V DC(-15%/+20%) Input current 70mA+(total GC-bus current)/maximum 2.5 A Starting current About 2.5 times continuous current GC-bus current supply 500mA Fuse capacity ≤10A Power supply Maximum 24V DC/maximum 10A Electrical isolation 1000Vrms(power contact/bus coupled poweroltage) Environmental testing Working temperature -40℃~+85℃ Working humidness 95%RH,without condensation EMC test EN 55024:2011-09 EN55022:2011-12 Anti-vibration/impact resistance performance EN60068-2-6/EN 60068-2-27/29 Anti-electromagnetic interference/radiation performance EN61000-6-2/EN61000-6-4 IP grade IP20 Basic information Dimension 100mm*69mm*44mm Weight 100g
- · Support standard Modbus protocol, a standard Modus slave station
· Support Modbus TCP, Modbus RTU communication (corresponding to two kinds of style)
· RS485 interface adopts standard two-wires system
· Serial interface baud rate supports 600bps~115200bps, configured by serial interface
· The maximum number of bus terminals module is 64
· Configuration mode is automatic configuration, expandedfreely
· Ethernet interface supports static or dynamic IP acquisition
· Ethernet interface supports heartbeat and timeout disconnection
· Ethernetwork interface is fixed, target IP and target interface can be set
· Automatic restoration of connection resources after the Ethernet interface is disconnected, and reliable establishment of TCP connections
· Ethernet interface is compatible with the SOCKET working mode (TCP Server, TCP Client, UDP, etc.). The upper computer communication software complies with the standard SOCKET rules.
· Supply power: 24V DC (-15%/+20%)
· Input current, 70mA+ (total GC-bus current), maximum 4500mA
· Starting current: about 2.5 times continuous current
· Power contacts: maximum 24V DC/maximum 10A
· Electrical isolation: 1000 Vrms (power contact/bus coupled powervoltage)
· Working temperature: -40.00℃~ 85.00℃
· Standard DIN rail,designed for industrial design
· Dimensions:100mm(L) * 69mm(W) * 48mm(H)
PLC Parameters Modbus protocol Modbus TCP,Modbus RTU Bus terminal module quantity Up to 32 modules The biggest byte number of profibus 32bytes input and 32bytes output Digital I/O signal 256 input/output Analog I/O signal 60 input /output Configuration mode automatic configuration Bus interface RJ45 Power 24V DC(-15%/+20%) Input current 70mA+(total GC-bus current)/maximum 2.5 A Starting current About 2.5 times continuous current GC-bus current supply 500mA Fuse capacity ≤10A Power supply Maximum 24V DC/maximum 10A Electrical isolation 1000Vrms(power contact/bus coupled poweroltage) Environmental testing Working temperature -40℃~+85℃ Working humidness 95%RH,without condensation EMC test EN 55024:2011-09 EN55022:2011-12 Anti-vibration/impact resistance performance EN60068-2-6/EN 60068-2-27/29 Anti-electromagnetic interference/radiation performance EN61000-6-2/EN61000-6-4 IP grade IP20 Basic information Dimension 100mm*69mm*44mm Weight 100g
Packing1. Standard package. Carton2. Customized design
Delivery Time2~5 days after receipt of your payment.
After-sales24-hour telephone after-sales service
Technical support
GCAN provide one year free after-sales warranty, lifetime free software and technical support.