Email: 3571909015@qq.com

中文 | English

Shenyang FuShiDe Technology Co.,Ltd.

News

Focus on CAN Bus for 10 years,CAN bus industry leading unit.

Your Location: Home > News > Industry news >

Resolve CAN acquisition issues in automated production lines

The customer is an equipment automation manufacturer, and the production line testing station needs to retain equipment operation bus data for factory testing and archiving. Adopting Guangcheng GCAN-402 dual channel CAN offline recorder, 2500V isolation, DC9~30V power supply, TF card cyclic storage of CAN messages, equipped with 0.1ms hardware timestamp, independent of the upper computer operation.

The equipment is installed in the electrical control cabinet of the testing station, synchronously collecting two CAN bus messages. After the test is completed, the ASC/CSV file is exported, and the engineer replays the station action timing data on the computer to retain the original bus records for the equipment's factory testing.

Guangcheng Technology GCAN-402 Product Official Website Link

https://www.gcgd.net/productinfo/288037.html

If you need Guangcheng Technology GCAN-402 to solve the problem of retaining raw bus records for automation equipment production line testing, you can add WeChat 13019325660 for professional technical service.