(18):GCAN-212
The traditional CAN bus transmission distance is limited, and the wiring of cross regional and distributed equipment in the factory is cumbersome. The frequency converter interference is prone to packet loss, and engineers can only go to the site for debugging, resulting in high inspection costs. The GCAN-212 dual CAN to Ethernet gateway perfectly solves the problem, with dual CAN channels with 1500V electrical isolation, supporting TCP/UDP multi-mode, long-distance stable transparent transmission of CAN data, and wide temperature body adaptation to harsh working conditions.
Real implementation case: A battery cabinet is arranged in multiple areas of an energy storage power station, and the original CAN wiring frequently disconnects across the factory area. The efficiency of daily on-site BMS data collection by operation and maintenance personnel is extremely low. After installing GCAN-212, the CAN signals in each area are converted to Ethernet and connected to the central control room. Staff can remotely read battery voltage and temperature messages from the duty room, and the network will automatically reconnect when disconnected, without the need to travel back and forth on site, resulting in a 60% increase in operation and maintenance efficiency.
Equipment adaptation for energy storage, automated production lines, smart fire protection, power monitoring, and other projects, supporting software configuration and supporting secondary development. For long-distance CAN networking and remote data collection needs, please call 13019325660 for a complete solution.
Real implementation case: A battery cabinet is arranged in multiple areas of an energy storage power station, and the original CAN wiring frequently disconnects across the factory area. The efficiency of daily on-site BMS data collection by operation and maintenance personnel is extremely low. After installing GCAN-212, the CAN signals in each area are converted to Ethernet and connected to the central control room. Staff can remotely read battery voltage and temperature messages from the duty room, and the network will automatically reconnect when disconnected, without the need to travel back and forth on site, resulting in a 60% increase in operation and maintenance efficiency.
Equipment adaptation for energy storage, automated production lines, smart fire protection, power monitoring, and other projects, supporting software configuration and supporting secondary development. For long-distance CAN networking and remote data collection needs, please call 13019325660 for a complete solution.
Last:(17):GCAN-211
Next:(19):GCAN-212B